ISSN : 0970 - 020X, ONLINE ISSN : 2231-5039
     FacebookTwitterLinkedinMendeley

Method Development and Validation for the Trace Level Quantification of Genotoxic Impurity Oseltamivir Phosphate Related Compound-a in Oseltamivir Phosphate Using LC-MS

Pikkili Viswanath1*, Doddipalli Venkata Ramana Reddy1 and Nagaraju Chamarthi2

1Department of Chemistry, S.G.Govt.Degree and PG College, Piler-517214, Andhra Pradesh, India.

2Department of Chemistry, Sri Venkateswara University, Tirupati-517502, Andhra Pradesh, India..

Corresponding Author E-mail: viswa_nath32@yahoo.com

DOI : http://dx.doi.org/10.13005/ojc/370525

Article Publishing History
Article Received on : 02-Sep-2021
Article Accepted on :
Article Published : 29 Oct 2021
Article Metrics
Article Review Details
Reviewed by: Dr. Senthamaraikannan Kabilan
Second Review by: Dr. K.A. Amin
Final Approval by: Dr. Soumyakanti Adhikari
ABSTRACT:

A selective and sensitive method has been developed for the determination of ethyl-(3S,4R,5S)-4-acetamido-5-amino-2-azido-3-(pentan-3-yloxy)cyclohexanecarboxylate (OSPRC-A) by using liquid chromatography coupled with mass spectrometer with single mass analyzer (LC-MS).The method was developed by using column DEVELOSIL ODS-UG-5, (50×3.0 mm, 5.0 µm) with linearity range of 0.005% to 0.0151% which meets to quantification level of 150% range. The column oven temperature was maintained at 40ºC. The flow rate was set as 1.5 mL/min. Injection volume was 10 µL and the detection wavelength was 215 nm. The signal to noise ratio values obtained were found to be 4.79 at concentration level of 0.00015% for the limit of detection (LOD) and 13.46 at concentration level of 0.0005% for the limit of quantification (LOQ). The % recovery was found to be in between the range 80.0% to 101.32% at LOQ to 150% level. The result obtained in method precision and intermediate precision are found to be within the specification limit. The percentage RSD for the content of OSPRC-A of method precision was 4.26. The percentage RSD for the content of OSPRC-A for intermediate precision was 4.00. The sample prepared in analytical solution was found to be stable for 24 h. This method can be used for the identification of impurity, OSPRC-A in Oseltamivir phosphate drug substances in its manufacturing.

KEYWORDS:

Antiviral drug; Genotoxic Impurity; Liquid Chromatography; OSPRC-A; Oseltamivir Phosphate;

Download this article as: 

Copy the following to cite this article:

Viswanath P, Reddy D. V. R, Chamarthi N. Method Development and Validation for the Trace Level Quantification of Genotoxic Impurity Oseltamivir Phosphate Related Compound-a in Oseltamivir Phosphate Using LC-MS. Orient J Chem 2021;37(5).


Copy the following to cite this URL:

Viswanath P, Reddy D. V. R, Chamarthi N. Method Development and Validation for the Trace Level Quantification of Genotoxic Impurity Oseltamivir Phosphate Related Compound-a in Oseltamivir Phosphate Using LC-MS. Orient J Chem 2021;37(5). Available from: https://bit.ly/3BtISs6


Introduction

Oseltamivir phosphate (OST) is a potent antiviral drug used for the treatment of influenza A and influenza B sold under the brand name Tamiflu. It inhibits the viral enzyme neuraminidase and prevents the virus budding from host cell, infectivity and replication1. Oseltamivir phosphate is an ester prodrug metabolized to Oseltamivir carboxylate in the liver by hepatic esterases. The drug half life is 1.8 h. After oral administration 80% metabolite shows the therapeutic action for about 30 min and 20% of the drug will be present 3-4 h in plasma. It was found that only 3% interaction with plasma protein2.Tamiflu was the first drug approved in October 1999 by USFDA for the treatment of influenza A and B in adults3. OST dosage regimen for adults is 75 mg twice daily for five days, but for prophylactic therapy 75 mg once a day for ten days4. OST is described chemically as ethyl (3S, 4R, 5S)-4-acetamido-5-amino-3-pentan-3-yloxycylohexene-1-carboxylate phosphate. Its empirical formula is C16H31N2O8P and molecular weight is 410.4 g/mol. Molecular formula of OST free base is C16H28N2O4 and molecular weight is 312.4 g/mol5. The structure of OST and its process related impurities are shown in the Fig.1. Literature survey revealed that oseltamivir phosphate related compound A (OSPRC-A) should be less than 100 ppm in OST when estimated by the LC-MS technique6. Different related substances are observed in different synthetic routes and never observed together in a selected synthetic route7. As per International Pharmacopoeia the limits of individual impurity in OST is 0.1% and total impurity should be not more than 0.7%. As a regulatory requirement all the impurities >0.1% must be analyzed quantitatively and reported8.

Figure 1: Chemical structures of Oseltamivir phosphate and OSPRC-A

Click here to View figure

The present study is mainly focused on known impurity of OST that is Oseltamivir phosphate related compound A (OSPRC-A) which is produced during the synthesis of Oseltamivir phosphate. The chemical name of OSPRC-A is ethyl (3S, 4R, 5S)-4-acetamido-5-amino-2-azido- 3-(pentan-3-yloxy) cylohexane-1-carboxylate.Its empirical formula is C16H29N5O4 and molecular weight is 355.43 g/mol9. OSPRC-A was found to be mutagenic when present in more than 0.03%.Oseltamivir phosphate passed Ames test when this related substance was not present and reported to be non mutagenic10.

Genotoxic Impurity

Genotoxic impurities are the chemical substances which can cause damage to the genetic materials DNA and RNA. Manifestation of genotoxic impurities in APIs and drug products received more attention by pharmaceutical industries and regulatory authorities due to their toxic effects on public health12. Young infants, immune compromised patients and severely ill persons are more prone to these genetic effects due to OSPRC-A13.

LC-MS as detection technique

LC-MS is a popular and versatile hyphenated technique used for the determination of related substances and impurities at parts per million levels14. The literature search disclosed that few methods were developed for estimation of Oseltamivir API alone by HPLC15-16, LC/MS/MS17, Spectrophotometry18, Desorption electro spray ionization mass spectrometry (DESI-MS)19. These factors drawn the attention of the author to develop a method and validate OST and   OSPRC-A by highly advanced technique LC-MS to control this related substance in the marketed product.

Materials and Methods

Chemicals and reagents

OST (as Oseltamivir Phosphate) and its impurity OSPRC-A were supplied by Perfomics Analytical  Lab, Hyderabad. HPLC grade methanol, acetonitrile were purchased from Merck, Mumbai, India. HPLC grade water was prepared by using Millipore purification system and used throughout the study. AR grade ethanol, ammonium acetate was procured from SD fine chemicals, Mumbai, India.

Chromatography conditions

A Waters UPLC TQD mass spectrometer (Waters Corporation, Milford, USA) equipped with PDA detector controlled by Empower software was used for the analysis. We achieved chromatographic separation of OST and Oseltamivir phosphate related compound-A using  column DEVELOSIL ODS-UG-55 (C18, 50 mm× 3.0 mm length, 5.0 µm diameter) manufactured by the phenomenex. The column oven temperature was maintained at 40ºC. The flow rate was set as 1.5 mL/min. Injection volume was 10 µL and the detection wavelength was 215 nm. HPLC grade water was used as diluent. Positive ion spray ionization (ESI) probe operated with SIM mode was used for the quantification of OSRPC-A.

Stock, standard and test solution preparation

Stock solution of OSPRC-A was prepared by weighing accurately about 2 mg of USP OSPRC-A standard into 100 mL volumetric flask and dissolved in diluent. Working standard solution was obtained by diluting 7.5 mL of standard stock solution of OSPRC-A into 20 mL volumetric flask and volume made up to the mark with diluents to get 0.0075% solution. Standard stock solution of oseltamivir phosphate working standard by weighing accurately 50 mg into 5 mL volumetric flask and dissolved by using solution-A. Test sample solution prepared by weighing 50 mg into 5 mL volumetric flask by using diluent. Analytical water was used as diluent.

Preparation of buffer solution and mobile phase

0.39 g of accurately weighed ammonium acetate was diluted to 1000 mL with milli Q water; its pH was adjusted to 5.0 with formic acid and filtered through 0.22 µ nylon membrane filter. Mobile phase was prepared by taking a mixture of acetonitrile, water and buffer in the ratio of 3:6:1 v/v/v and filtered through 0.45 µ membrane filter and degassed by ultrasonication.

Optimization of mass spectrometer parameters

To get the most abundant ion of OSPRC-A, injected the 1 mg/mL solution through direct infusion method which contain syringe and syringe pump to deliver a regular flow of liquid sample. Initially low sensitivity of ions are observed with flow rate of 10 µL/min at different mass parameters, later increased the flow rate 30 µL/min to get maximum sensitivity of ion by changing the mass parameters in different ways. Final optimized mass parameters are given in Table 1.

Table 1: Optimized mass and source spectrometer parameters

S.No.

Mass parameters

S.No.

Mass parameters

1

Ionization mode

Electro spray ionization

7

Extractor[V]

3.0

2

Acquisition mode

Single ion monitoring

8

RF lens[V]

0.3

3

Polarity mode

Positive

9

Source Temp[°C]

120

4

Ion

356.03[M+H]+

10

Desolvation Temp[°C]

350

5

Capillary [KV]

3.50

11

Cone gas flow[L/Hr]

50

6

Cone [V]

25.0

12

Desolvation gas flow[L/Hr]

950

7

Split ration

3:1

 

 

 

 

Results and Discussion

Method validation has been performed as per ICH guidelines. In this study, validation parameters viz; system suitability, specificity, solution stability, LOD and LOQ, accuracy, method precision, linearity and intermediate precision were established to validate the method for the reproducibility of results. System suitability check was done by injecting the six standard solutions and %RSD was within the limits. Specificity was performed to check the interference at the RT of peak interest with blank, standard and spiking solution and it is seen that there is no peak interference at the retention time of OSPRC-A.

OSPRC-A standard solution was taken and analyzed for solution stability at 5°C temperature after 7 and 11 hours. LOD and LOQ were established by considering the concentration of OSPRC-A which would get signal to noise of 3:1 and 10:1 respectively. Precision was evaluated with six LOQ standard solutions to check the reproducibility of result. Accuracy was established at LOQ, 50%, 100% and 150% interval and recovery found within the specification limit. Method precision was established by spiking the OSPRC-A in OST test sample and % RSD found satisfactory. Linearity range was conducted for OSPRC-A and the range from LOQ level to 150% of limit.

Method development

For the identification of OSPRC-A impurity in Oseltamivir phosphate many trials were done by using different buffers, chemical, solvents and column in isocratic and gradient chromatographic mode by using high performance liquid chromatography (HPLC), but low sensitivity has been achieved in HPLC. Hence, method development trials extended to liquid chromatography coupled with single mass spectrophotometer (LC/MS) to achieve the sensitivity of OSPRC-A at limit of detection level.  In addition various additives such as trifluoroacetic acid, formic acid, methanol and acetonitrile have been tested. Number of trials were done by using different buffers, chemicals and solvents like trifluoroacetic acid, formic acid, methanol and acetonitrile and columns which includes C18, C8 and cyano columns to achieve good shape, response and repeatability of results, finally the separation of OSPRC-A and Oseltamivir phosphate achieved in Develosil ODS-UG-5 50×3.0 mm length, 5.0 µm diameter column and mobile phase a mixture of acetonitrile, water and buffer in the ratio of 3:6:1 v/v/v. The flow rate was 1.5 mL/min. Determination of OSPRC-A, hampered by inadequately sensitive analytical methods and impurity sample volume limitations. Hence, a very sensitive assay for the quantification of OSPRC-A in OST drug substance in manufacturing of OST drug products is highly required without compromising high sensitivity is particularly attractive.

Validation study

The developed method was validated in terms of system suitability, solution stability, specificity, linearity, accuracy, precision, and robustness, LOQ and LOD. Validation was carried out as per the ICH guidelines. The method validation was started by injecting 0.01% solution of OSPRC-A with respect to 5 mg/mL of OST and their Signal/Noise ratios determined. Now to determine LOD and LOQ values OSPRC-A concentration was reduced sequentially such that they yield S/N ratios as 3:1 and 10:1 respectively.

Linearity of OSPRC-A was fixed in the range of LOQ to 150% (0.0005%-0.0151%) of the estimated permitted level. Therefore 40%, 80%, 100%, 120% and 150% solutions of OSPRC-A was prepared and injected individually. The calibration curve was plotted between concentration Vs peak area of OSPRC-A. Repeatability was checked by calculating %RSD of six replicate determinations by injecting six freshly prepared solutions containing 0.01% of OSPRC-A on the same day. The same experiment was repeated for six different days to find out intermediate precision. The accuracy of the method was determined by spiking known amount of sample at different intervals and spiked with a known amount of OSPRC-A (LOQ to 100% level).

System suitability

System suitability performance is a main criterion to know the precision of the instrument. Hence, the system suitability was established by injecting the six replicate injections standard solution and calculated the % RSD for peak area of Oseltamivir phosphate related compound A. The data was given in Table 2. The % RSD of OSPRC-A peak obtained from six replicate injections of standard and cumulative % RSD from six replicate injections with online standard found within the specification limit against pre-defined specification i.e. % RSD should not be more than 15.0%.

Table 2: System suitability parameters of OSPRC-A

Injection no.

Area of OSPRC-A

1

517685

2

526986

3

539727

4

536846

5

529682

6

534425

Avg. area

530891.8

SD

7964

%RSD

1.50

 

Specificity

Specificity study established for OSPRC-A by injecting the blank solution and standard solution followed by spiked standard solution to know the interference of any known and unknown impurity at retention time of OSPRC-A. No interference was observed at retention time (1.160 min) of the OSPRC-A in blank. Retention time of the OSPRC-A were comparable in standard and spiked standard solution. The chromatographic details are shown in Fig.2 and Fig.3.

Figure 2: OSPRC-A standard chromatogram

Click here to View figure

Figure 3: OST and OSPRC-A spike chromatogram

Click here to View figure

Solution Stability

To know the short time shelf life of the analyte in prepared solution, solution stability was established for OSPRC-A in OST sample by injecting the fresh standard and test samples. The solutions were stored at 5 ºC temperature for 7 h and 11 h. The variation in the content obtained from solution stability study was within the limit with respect to the defined specification limit ±30% of the specification limit for genotoxic impurities.

Limit of Detection (LOD)

Detection limit experiment performed for OSPRC-A to know the lowest detection limit by the method. LOD standard solution was prepared with respect to the test concentration as 0.00015%, so as obtained signal to noise was 4.79 and the chromatogram is shown in Fig.4.

Figure 4: OSPRC-A LOD chromatogram

Click here to View figure 

Limit of Quantification (LOQ)

Quantification limit was established for OSPRC-A based on the concentration obtained from LOD, LOQ standard solution was prepared 3 times to LOD concentration (0.0005%),  so as obtained the S/N ratio about 13.46. The low values of LOD and LOQ indicate an adequate sensitivity of the method.

Precision at LOQ

To check the closeness of the measurement to the predefined specific limit, precision experiment is performed with LOQ standard solution of OSPRC-A. LOQ standard solution was injected six times and calculated % RSD. The % RSD observed for six replicates of LOQ solution was observed to be 1.93 which was well within acceptance criteria, not more than 15.0.The result is summarized in Table 3 and the related chromatogram is shown in Fig.5.

Table 3: Precision of OSPRC-A at LOQ level

LOQ Standard solution

Area of OSPRC-A

Injection-1

34871

Injection-2

35472

Injection-3

35264

Injection-4

33647

Injection-5

35268

Injection-6

34963

Average

34914

SD

659

% RSD

1.89

 

Figure 5: OSPRC-A LOQ chromatogram

Click here to View figure 

Accuracy

Accuracy study is established to check recovery of analyte when unknown sample spiked in known concentration sample at different levels. So the test sample was analyzed three times (from three individual preparations) for accuracy studies by spiking with OSPRC-A at LOQ, 50%, 100% and 150% levels and calculated the % recovery of OSPRC-A in OST. The % recovery of OSPRC-A was in the range of 80.0 to 101.0 at LOQ, 50%, 100% and 150% level. Accuracy results are summarized in Table 4. It was observed that the method was accurate within the specified range.

Table 4: % Recovery of OSPRC-A at LOQ, 50%, 100% and 150% level

Accuracy levels

No. of preparations

% Recovery of OSPRC-A

LOQ

1

100.00

2

100.00

3

80.00

50%

1

88.00

2

96.00

3

88.00

100%

1

90.10

2

99.01

3

97.03

150%

1

100.66

2

101.32

3

100.66

 

Linearity

Linearity study was conducted for oseltamivir phosphate related compound A and the linearity range from LOQ level to 150% of limit. Correlation coefficient value for OSPRC-A was derived from the linearity graph and it is found to be 0.998. Results are given in Table 5 and the graph is represented in Fig.6.

Table 5: Linearity for OSPRC-A

Level

Concentration (%)

Area of OSPRC-A

Level-1

0.0005

35264

Level-2

0.0050

344339

Level-3

0.0075

531982

Level-4

0.0101

676087

Level-5

0.0126

864106

Level-6

0.0151

996329

 Correlation  coefficient

0.998

Figure 6: Linearity graph for OSPRC-A

Click here to View figure 

Method Precision

OST test sample was spiked with OSPRC-A at specification level with respect to the test sample concentration for six times and analyzed for the method precision study.

Intermediate precision

To prove the reproducibility of the method, precision study was done on a different day and with different analyst by using different column with freshly prepared solutions. Variation between the method precision and intermediate precision are given in Table 6. The result obtained in method precision and intermediate precision are found to be within the specification limit. The percentage RSD for the content of OSPRC-A of method precision was 4.26 (acceptance limits not more than 10.0). The percentage RSD for the content of OSPRC-A for intermediate precision was 4.00 (acceptance limits not more than 10.0).

Table 6: Summary of results for method precision and intermediate precision

Preparations

Content OSPRC-A (%)

Method precision preparation-1

0.0092

Method precision preparation-2

0.01

Method precision preparation-3

0.0098

Method precision preparation-4

0.0091

Method precision preparation-5

0.009

Method precision preparation-6

0.0093

Intermediate precision preparation-1

0.0095

Intermediate precision preparation-2

0.0101

Intermediate precision preparation-3

0.0101

Intermediate precision preparation-4

0.0092

Intermediate precision preparation-5

0.0093

Intermediate precision preparation-6

0.0091

Average

0.0095

SD

0.0004

Cumulative % RSD

4.4

 

Conclusion

A simple analytical method was developed and validated for the trace level quantification of genotoxic impurity. OSPRC-A in OST drug substance by using liquid chromatography coupled with mass spectrometer. Full validation was done for the method and established the specificity, linearity, accuracy, precision and ruggedness. The method exhibited an excellent performance in terms of sensitivity and specificity and also found to be simple, precise and cost effective, because the method was developed and validated with single mass analyzer with isocratic mode chromatographic condition. The LOD and LOQ established at low concentration and S/N found to be 4.79 and 13.46 respectively.  The sample prepared in analytical solution was found to be stable for 24 h. Hence this method can be used for the identification of impurity, OSPRC-A in OST drug substances in its manufacturing.

Acknowledgement

The authors are thankful to the Perfomics Analytical  Lab, Hyderabad for supporting and providing the analytical instruments, chemicals and solvents for development and validation of OSPRC-A by using liquid chromatography coupled with mass spectrometer.

Conflicts of Interest

The authors declare that there is no conflict regarding publication of this manuscript.

Funding Sources

There are no funding source

References

  1. Dutkowski, R. Oseltamivir in seasonal influenza cumulative experience in low and high risk patients. J of Antimicrob Chemother., 2010, 65(2), 11-24. doi: 10.1093/jac/dkq012.
    CrossRef
  2. Aoki, F.Y, Doucette, K. E.Oseltamivir a clinical and pharmacological perspective. Expert Opinion on Pharmacotherapy., 2001, 2(10), 1671-1683. doi: 10.1517/14656566.2.10.1671
    CrossRef
  3. Gupta, Y., Meenu., M.,  Mohan, P.The tamiflu fiasco and lessons learnt. Indian J Pharmacology., 2015, 47, 11-16.  doi: 10.4103/0253-7613.150308.
    CrossRef
  4. Dutkowski, R,. Smith., J.R., Davies, B.ESafety and pharmacokinetics of oseltamivir at standard and high dosages. Int J Antimicrob Agent., 2010,35 (5), 461–467. doi: 10.1016/j.ijantimicag.2009.12.023.
    CrossRef
  5. Drugbank.com, Oseltamivir https://go.drugbank.com/drugs/DB00198. Accessed, July-3, 2021.
    CrossRef
  6. The International Pharmacopoeia. 2018. 8th  Edition. https://apps.who.int/phint/en/p/docf/ Accesssed, July-3, 2021.
    CrossRef
  7. Sharma, Y. K., Agarwal, D. D., Bhure, S., Rathore, S. S., Rawat, C., Mukharjee, R Synthesis, isolation and characterization of process related impurities in oseltamivir phosphate. Journal of Chemistry., 2012,  9(1), 113–120. https://doi.org/10.1155/2012/327351
    CrossRef
  8. ICH Q3B (R2) (2003). Impurities in New Drug Products.
  9. Chemical Book.com, Oseltamivir phosphate related compound A. https://www.chemicalbook.com/ChemicalProductProperty_EN_CB71475965.htm  Accessed, July-3, 2021.
  10. Pubchem, Oseltamivir, https://pubchem.ncbi.nlm.nih.gov/ compound/Oseltamivir Accessed, July-3, 2021.
  11. Sagar Kishor Savale.Genotoxicity of drugs introduction, prediction and evaluation. Asian J Biomaterial Res., 2018, 4 (6),1-29.
  12. Szekely, G., Amores de Sousa, M. C., Gil M., Castelo Ferreira, F.,  Heggie, W. Genotoxic Impurities in Pharmaceutical Manufacturing Sources, Regulations and Mitigation. Chemical Reviews., 2015,115, 8182–8229. https://doi.org/10.1021/cr300095f
    CrossRef
  13. Reddy, D.Responding to pandemic (H1N1) (2009) influenza the role of oseltamivir. J Antimicrob Chemother., 2010, 65(2), 35–40. doi: 10.1093/jac/dkq014.
    CrossRef
  14. Akshatha, H.S., Gurupadayya, B.M.,Application of liquid chromatography coupled with mass spectrometry in the impurity profiling of drug substances and products. Asian J Pharm Clin Res., 2018, 11(5), 30-37. https://doi.org/10.22159/ajpcr.2018.v11i5.24212
    CrossRef
  15. Narasimhan, B., Abida, K.,  Srinivas, K.,Stability Indicating RP-HPLC Method Development and Validation for Oseltamivir API. Chemical and Pharmaceutical Bulletin., 2008, 56(4), 413–417. doi: 10.1248/cpb.56.413.
    CrossRef
  16. Joseph Charles, J., Geneste C., Laborde Kumme E., Gheyouche, R., Boudis, H.,  Dubost, J. P., Development and validation of a rapid HPLC method for the determination of oseltamivir phosphate in tamiflu and generic versions. J Pharm Biomed Anal., 2007, 44(4), 1008–1013. doi: 10.1016/j.jpba.2007.04.002.
    CrossRef
  17. Lindegardh, N., Hanpithakpong, W., Wattanagoon, Y., Singhasivanon, P., White, N. J.,  Day, N.P.J.,Development and validation of a liquid chromatographic tandem mass spectrometric method for determination of oseltamivir and its metabolite oseltamivir carboxylate in plasma, saliva and urine. J Chromatogra B., 2007, 859(1), 74–83. doi: 10.1016/j.jchromb.2007.09.018.
    CrossRef
  18. Omar, M.A., Derayea, S.M.,  Mostafa, I.M.,  Selectivity improvement for spectrofluorimetric determination of oseltamivir phosphate in human plasma and in the presence of its degradation product. J of Fluorescence., 2017, 27(4), 1323–1330. DOI: 10.1007/s10895-017-2066-6
    CrossRef 
  19. Nyadong, L., Hohenstein, E. G., Johnson, K., Sherrill, C. D., Green, M. D.,  Fernandez, F. M.,Desorption electrospray ionization reactions between host crown ethers and the influenza neuraminidase inhibitor oseltamivir for the rapid screening of tamiflu. The Analyst., 2008, 133(11), 1513.
    CrossRef

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

About The Author