Abstract
Methods of Reducing the Front Performance Flame at the Underground Mines Works
M. I. Tulepov1,2, Z. A. Mansurov1,2, Yu. V. Kazakov1,2, F. Yu. Abdrakova1,2, Z. L. Sultanova1, N. M. Rakhova1,2, S. S. Madiyev 1, O. Yu. Golovchenko1,2, L. R. Sassykova1,2, D. M. Tolep1, N. Chikhradze3 and M. N. Chikhradze3
DOI : http://dx.doi.org/10.13005/ojc/340645
Abstract:
The aim of the study was to develop methods to reduce the penetration ability of the flame front and red-hot striking elements that propagate in the confined space of mines. In the article is considered a method for localizing explosions of a methane-dust mixture in coal mines, by creating an aqueous barrier (increased density) in the propagation path of the flame front and incandescent particles, using a high-energy pyrotechnic composition based on nanoaluminum. The optimal pyrotechnic composition contents of ammonium nitrate - 50%, smokeless powder - 45%, magnesium - 3% and nanoaluminum - 2%. This composition punched the target to a depth of 6.5 mm with a barrier thickness of 50 mm. Water cannon with a nozzle with a diameter of 80mm, allows to localize the spread of the flame front.
Keywords:Magnesium; Nanoaluminum; Pyrotechnic Composition; Smokeless Powder
Back to TOC