ISSN : 0970 - 020X, ONLINE ISSN : 2231-5039
     FacebookTwitterLinkedinMendeley

Improved Method for the Determination of Inorganic Anions in Roselle (Hibiscus sabdariffa L.) by Suppressed Ion Chromatography

Shaker J. Azhari

Department of chemistry, Faculty of Applied Sciences, Umm AL-Qura University, P.O Box 7605, Makkah, Kingdom of Saudi Arabia.

Article Publishing History
Article Received on :
Article Accepted on :
Article Metrics
ABSTRACT:

A smpile, rapid and accurate method for the determination of main mono and divalent inorganic anions in Roselle (Hibiscus sabdariffa L.) has been developed. The quantitative determination of anions F-, Cl-, NO-2, Br-,NO-3, HPO2-4,SO2-4, and I- was accomplished by suppressed conductimetric ion chromatography (IC). The separation is achieved on shim-pack IC-SA2 250 mmL X 4.0 mm ID Peak. column operated at 30°C within 12.21 minutes by isocratic elution with 1.8 mM  potassium carbonate, 12 mM Potassium bicarbonate and 0.0125mM of N- {[(ethylamino) thioxomethyl] hydrazine carbonlmethyl} trimethyl ammonium chloride (ETHTC) and pH 9.25 as eluent at flow rate of 1ml/min. The method does not need a special sample treatment.

KEYWORDS:

Optimization; determination; inorganic anions; ETHTC; Roselle (Hibiscus sabdariffa L) suppressed ion chromatography

Download this article as: 

Copy the following to cite this article:

Azhari S. J. Improved Method for the Determination of Inorganic Anions in Roselle (Hibiscus sabdariffa L.) by Suppressed Ion Chromatography. Orient J Chem 2012;28(1).


Copy the following to cite this URL:

Azhari S. J. Improved Method for the Determination of Inorganic Anions in Roselle (Hibiscus sabdariffa L.) by Suppressed Ion Chromatography. Orient J Chem 2012;28(1). Available from: http://www.orientjchem.org/?p=24000


Introduction

Ion chromatography (IC) is one of the simplest and most effective techniques to determine both anions and cations owing to its high sensitivity, rapidity and ease of operation [1-3].The presence of ligand in the composition of mobile phase and its effect on the resolution has been reported by several authors [4-14].It has been reported that the inclusion of EDTA in the mobile phase yields increased resolution and peak symmetry [10].The addition of 18-crown-6 to an eluent has been known to be very effective in improving peak resolution between monovalent cations [9, 15, 16]. This behavior can be explained by stability constant of complexation of alkali metal ions with 18-crown – 6 absorbed on cation-exchange resion of separation column [17].

Also the use of ligand assist too much in solving the problem of overlapping of some inorganic anions and organic acids [4,13,14]. Moreover the presence of ligand in composition of mobile phase increase the sensitivity detection of the separated ions as well as reducing the retention time of the separated ions [11-14].The first objective of the present work to contribute more information about the effects of added N- {[(ethylamino) thioxomethyl]  hydrazine carbonylmethyl} trimethy ammonium chloride (ETHTC) on the optimization, sensitivity and detection limits of some inorganic anions by suppressed ion chromatography determination and their separation in the presence of ETHTC. Roselle (Hibiscus sabdariffa L.), an annual shrub, is commonly used to make jellies, jams, and beverages. The brilliant red color and unique flavor make it a valuable food product.

Nowadays, a great interest exists in the crop of Roselle due to the high antioxidant properties of the flowers calyxes. Which have been extensively evaluated [18-22]. Also the nutritional composition (proximate composition, amino acids, fibre and minerals) of Roselle has been reported [23]. Because of the importance of Roselle it was planned to study and contribute more information on the simultaneous determination of inorganic anions in Roselle as the second objective since no attention has been paid for the separation and determination of inorganic ions in Roselle. (Hibiscus sabdariffa L.)

Experimental

Apparatus

In this study analysis and data collection were performed by LC Solution software using a HIC-20A SUPER ion chromatograph purchased from shimadzu consisting of an LC-20 ADsp liquid delivery pump, a DGU-20 A, Degasser, Rheodyne (77251) injection valve with a 20 mL sample loop, CTO-20 ACsp column oven, CDD-10 Asp  conductivity detector, and SCL – 10 Asp system controller. The anion exchange column (Shim-pack IC-SA 2-250 mmL X 4.0 mm ID PEEK). The column oven was maintained at 30°C.

Reagents

All the inorganic anions in this study were of analytical reagents and were purchased from BDH chemical poole England.

N- {[(ethylamino) thioxomethyl] hydrazine carbonylmethyl} trimethyl ammonium chloride (ETHTC) was prepared as reported earlier [27]. Double distilled deionized water was filtered through 0.2mm whatman membrane. All standard solution eluents and reagents were prepared in double distilled deionzed water and filtered through 0.2mm whatman membrane filter.

2.3 Sample preparation

20g of Roselle (Hibiscus Sabdariffa L.) was plased in a flask containing 70 ml double distilled dionized water. The mixture was heated at different temperature (60, 70, 80 and 90°C) for 5, 10, 15, 20, 25 and 30 minutes. After cooling the solution was filtered through 0.2mm whatman membrane filter and then the filtered solution was transferred to 100 ml flask and double distilled deionized water added to the mark. This sample solution was injected into the ion chromatograph. This sample was run ten times. 

2-4 The optimum conditions

The optimum analytical conditions have been established in this method in order to separate, and determine eight inorganic anion simultaneously using isocratic method with 1.8 mM potassium carbonate and 12 mM potassium bicarbonate at pH 9.24, flow rate 1ml/min and at 30°C the data obtained was compared with the eluent solution containing 0.0125 mM ETHTC in addition to the above mentioned eluent at pH 9.25 and flow rate 1 ml/min.

Results and discussion

Effect of concentration of potassium carbonate on retention volumes VR of mono and divalent anions.

The effect of concentration of potassium carbonate in the eluent on the retention volumes of mono and divalent anion  was investigated for the simultaneous separation of these anions.

Fig 1: Shows the relationship between the concentration of potassium carbonate in the eluent and the retention volumes of these mono and divalent anions. From fig 1 it can be concluded that the retention volumes of these anion decreased drastically for  and  while it is slightly decrased for  with increasing the concentration of potassium carbonate, also the shortest retention volumes was obtained with the concentration of 1.75 mM potassium carbonate for the all anions under investigation, in addition the optimum concentration was found to be 1.8 mM potassium carbonate and overlapped for  and  appeared at the concentration of 1.8 mM potassium carbonate. The solution of this overlap will be discuss in the ETHTC effect section.

The effect of flow rate of eluent on retention behavior of mono and divalent anions.

Several flow rate values ranging from (0.45 -1 ml/min) were used in this study in order to achieve optimum resolution time. Table 1 and fig 2 indicate that the retention volumes decrease with increasing the flow rate, Also the shortest retention volume was obtained with the flow rate 0.9 ml/min for all the ions under studies, moreover the results revealed that the excellent separation of inorganic anions under investigation obtained by using flow rate 1 ml/min for  and  and it gave more repeatability than other flow rate studied, in addition the separation at flow rate 1 ml/min revealed that there are overlap between   and  ,section 3.5 will discuss the solution of this problem.

Table 1The influence of flow rate on the retention of analytes

Flow rate

Cl¯

NO2¯

Br¯

NO3¯

HPO4¯¯

SO4¯¯

0.45

6.572

7.284

9.021

10.451

13.879

14.896

17.141

20.468

0.65

5.594

6.014

7.986

8.895

11.917

13.965

14.693

17.883

0.85

4.372

5.01

6.859

7.685

8.893

10.112

11.601

15.764

0.9

4.103

4.628

6.697

7.232

8.399

8.812

10.659

15.102

1

3.122

4.444

5.181

6.116

6.755

6.755

8.409

14.373

 

3.3 Effect of pH of eluent on retention behavior of mono and divalent anions.

In this study different pH values were examined ranging from (8.99 – 9.24) In order to get a good and fast separation. Fig 3 and table 2 shows the relationship between the pH of eluent and the retention volumes of the mono and divalent anions. The data obtained indicates that the retention volumes of the anions under investigation decreased with increasing the pH of the eluent. Also the results revealed that the most efficient separation of inorganic anions under studies (except  and ) was obtained with the pH 9.24. The solution of the overlap between  and  will be discuss in section 3.5.

Table 2 : The effect of the eluent pH on retention behavior of anions

pH

Cl¯

NO2¯

Br¯

NO3¯

HPO4¯¯

SO4¯¯

8.99

3.207

6.451

10.171

15.723

19.101

21.457

23.702

29.273

9.04

3.191

5.927

9.133

13.921

16.829

18.219

19.976

26.478

9.07

3.137

5.939

7.927

12.107

13.672

15.217

17.227

24.213

9.14

3.162

5.307

6.968

10.531

11.623

12.829

15.141

21.237

9.18

3.146

4.912

6.207

8.731

9.378

10.712

12.211

18.131

9.21

3.129

4.523

5.373

6.769

7.526

8.216

9.321

15.568

9.24

3.122

4.444

5.181

6.116

6.755

6.755

8.409

14.373

 

3.4. The effect of column temperature:

The effects of column temperature and eluent strength on the retention volumes of analytes are shown in fig 4a, 4b and 4c.

The results are allotted in table 3. At all three temperature, the retention volumes of all the inorganic anions increase with increasing the eluent concentration from 0.75 up to 1.8 mM. The magnitude of the increases was in the following descending order: .

Table 3 : The influence of column temperature.

Temperature

°C

Concentration

( mM )

Cl¯

NO2¯

Br¯

NO3¯

HPO4¯¯

SO4¯¯

25

0.75

5.301

6.322

6.921

8.012

9.123

10.201

11.251

15.321

0.95

5.365

6.401

7.011

8.271

9.237

10.272

11.323

15.468

1.15

5.372

6.462

7.112

8.372

9.371

10.362

11.401

15.598

1.35

5.415

6.484

7.213

8.481

9.472

10.478

11.521

15.701

1.55

5.502

6.524

7.322

8.571

9.592

10.512

11.626

15.792

1.75

5.612

6.631

7.417

8.678

9.674

10.633

11.701

15.837

1.8

5.736

6.747

7.498

8.798

9.877

10.723

11.812

15.992

28

0.75

4.123

5.241

6.101

7.123

7.311

8.212

9.332

14.121

0.95

4.234

5.251

6.21

7.214

7.456

8.345

9.452

14.229

1.15

4.341

5.341

6.321

7.345

7.566

8.461

9.562

14.391

1.35

4.456

5.421

6.455

7.501

7.639

8.581

9.675

14.521

1.55

4.569

5.501

6.567

7.599

7.787

8.672

9.821

14.639

1.75

4.691

5.592

6.612

7.627

7.824

8.778

9.989

14.781

1.8

4.821

5.624

6.701

7.798

7.978

8.99

10.012

14.901

30

0.75

2.611

3.43

4.498

5.211

5.421

6.123

7.541

12.323

0.95

2.741

3.601

4.527

5.498

5.632

6.341

7.797

12.421

1.15

2.872

3.71

4.622

5.643

5.736

6.47

7.846

12.556

1.35

2.86

3.73

4.737

5.747

6.102

6.561

7.958

12.675

1.55

2.901

4.198

4.877

5.832

6.472

6.631

8.135

13.021

1.75

2.998

4.236

4.901

5.889

6.552

6.651

8.216

13.521

1.8

3.122

4.444

5.181

6.116

6.755

6.755

8.409

14.373

 

Also, the retention volumes for the seven eluent strength decrease when the column temperature increase from 25 to 30°C and the magnitude of the decrease was in the following descending order:. The response of the retention volumes of all the inorganic anions to the change in two factors (column temperature and eluent strength) were not liner, moreover the results indicate that the resolution at 30°C and concentration 1.8 mM for potassium carbonate gives the shortest retention volume. On comparing our results with Qiu’s method [24] we observed that the process of selection of temperature and eluent strength is very easy. In addition our results of the optimum conditions enable us to reduce the retention volumes for the eight inorganic anions form 15.992 to 14.373.

3.5: The effect of ETHTC on retention volume VR and sensitivity:

The addition of ETHTC to the eluent was carried out to improve Peak resolution between inorganic anions under investigation. Different concentration of ETHTC (0.0120 , 0.0125 and 0.013 mM) where added to 1.8 mM K2CO3 + 12 mM KHCO3 mobile phase in an attempt to effect the retention of inorganic anion under study. These results were compared to those obtained with the same column but without the addition of ETHTC. Fig 5 Shows that at all the three different concentration (0.0120 , 0.0125 and 0.013 mM) of ETHTC add to the same mobile phase the overlap between  and  has been solved and the concentration of 0.0125 mM ETHTC gaves the shortest retention volumes. On comparing our results with data of J. D., Lamb et al (4), L.L, pera et al [25] and Sangita D.Kumar et al [26] we found our results more satisfactory. J.D. lamb et al [4], investigated the separation of eight anions include

and  using 15 mM KOH + 2.5 mM 18- crown – 6 as eluent. The results revealed that the time of separation is around 20 minutes.

L.L., Pera et al [25] also studied the separation of eight anion include and using 3.12 mM Na2CO3 + 3.25 mM NaHCO3 + 2% acetone as eluent. The results indicate that the time of separation is around 14 minutes.

Sangita D. Kumar et al [26] also investigated the separation of seven anions include  and using 1.3 mM Na2CO3 + 2 mM NaHCO3 as eluent. The results revealed that the time of separation is around 35 minutes.

On the other hand our studies involve the separation of eight anion include  and and the time of separation is 12.21 minutes.

The results suggest that our method gives better results than that done by J. D. Lamb et al (4), L.L. Pera et al [25] and Sangita D. Kumar et al [26].

Also in our previous papers [14, 28] we investigated the separation of eight anions include  and using 1.8 mM K2CO3+ 12 mM KHCO3 + 5% ACN and 1.8 mM K2CO3 + 12 mM KHCO3 + 0.05 mM 18 – crown -6 as eluent respectively, the results revealed that the time of separation is 12.126 and 11.517 respectively. This means that the results obtained by both two papers (14, 28) and recent work, the use of 18-crown -6 gives better results than use of ACN and ETHTC as a composition of eluent but the use of ETHTC gives better results than the use of ACN as a composition of eluent.Figs (6) and (7) shows the simultaneous separation of inorganic anions before and after adding ETHTC to the eluent while Fig.(8) shows the sensitivity of before and after adding ETHTC.

In conclusion the presence o ETHTC increase the sensitivity and decrease the retention time from 14.373 to 12.21 minutes. The detection limit (S/N = 3) for eight inorganic anions ore given in table (4). The detection limit obtained by using the mixture of 1.8 mM K2CO3+ 12 mM KHCO3+ 0.0125 mM ETHTC, pH 9.25 are lower several time than those obtained by using 1.8 mM K2CO3+12 mM KHCO3 , pH 9.24.

Table (4) shows that the calibration graph for all inorganic anions under studies were linear with regression coefficient (r2) of 0.9991 – 0.9997.

Table 4 :Detection limit ( S/N=3 ),linear range of inorganic anions and regression coefficient.

Compound

Detection limit ( mg / L )

Linearity

Range (mg/L)

Regression

Coefficient

( r2)

1.8mM K2CO3+

12mM KHCO3

1.8mM K2CO3+

12mM KHCO3+

0.0125 mM ETHTC

F¯

0.10

0.0032

0.5-3100

0.9991

Cl¯

0.01

0.0023

0.5-3100

0.9997

NO2¯

0.13

0.12

0.5-2400

0.9992

Br¯

0.10

0.0023

0.5-2900

0.9992

NO3¯

0.0023

0.5-3100

0.9997

HPO4¯¯

0.0025

0.5-2600

0.9992

SO4¯¯

0.11

0.0037

0.5-4100

0.9995

I¯

0.11

0.0032

0.5-3400

0.9995

 

Application

From our acquaintance in the literatures, it has been appeared that there is no study in ion chromatography take up the point of separation and determination of inorganic anions in Roselle (Hibiscus sabdariffa L.) by using ion chromatographic technique.

Therefore, the new established method by using the mobile phase consisting of 1.8 mM Potassium carbonate + 12 mM Potassium hydrogen carbonate + 0.0125 mM ETHTC has been successfully applied to the separation and determination of inorganic anions in Roselle (Hibiscus sabdariffa L.) .

Table (5) summarizes the determination and reproducibility of anion (n = 10) in Roselle (Hibiscus sabdariffa L.) sample. So, the data shows that the peak area of each analyte were different at the different temperature (60, 70, 80 and 90°C) for the six heating times (5, 10, 15, 20, 25 and 30 min) only six anions were found in the sample include  and  ) and it was appeared at different temperature and different time,  and  appeared at 60°C at the heating time of 10, 20 and 30 minutes respectively and only  appeared at 70°C for a heating time 15 minutes, while  and  appeared at 80°C at 5 and 10 minutes respectively in addition the results shows the absence of  and  at variant temperature for variant heating time under our study, probably their concentration in sample were below the limit of detection of the present method. Also the results revealed that the amount of extraction increased with increasing the temperature from 60 to 90°C and also the heating time from 5 to 30 minutes. So, it can be concluded that the most suitable temperature and heating time is 90°C and 30 minutes.

Table 5:The concentration of inorganic anions (ppm) in hibiscus at different temperature (ppm).

Temp

°C

Time

( min )

Mean

and

RSD%

Cl¯

NO2¯

Br¯

NO3¯

HPO4¯¯

SO4¯¯

60

5

A

ND

ND

ND

ND

ND

ND

ND

ND

b

ND

ND

ND

ND

ND

ND

ND

ND

10

A

ND

ND

ND

ND

ND

ND

65.2

ND

b

ND

ND

ND

ND

ND

ND

1.21

ND

15

A

ND

ND

ND

ND

ND

ND

72.1

ND

b

ND

ND

ND

ND

ND

ND

1.22

ND

20

A

ND

4.5

ND

ND

ND

ND

84.2

ND

b

ND

0.94

ND

ND

ND

ND

1.13

ND

25

A

ND

5.1

ND

ND

ND

ND

93.4

ND

b

ND

0.93

ND

ND

ND

ND

1.12

ND

30

A

ND

5.9

ND

ND

ND

21.1 107.6

ND

b

ND

0.91

ND

ND

ND

1.22 1.16

ND

70

5

A

ND

35.6

ND

ND

ND

32.2

202

ND

b

ND

0.96

ND

ND

ND

0.56

0.46

ND

10

A

ND

48.7

ND

ND

ND

38.9

246

ND

b

ND

0.71

ND

ND

ND

0.76

0.43

ND

15

A

5.5

88.7

ND

ND

ND

44.3

261.4

ND

b

1.22

0.32

ND

ND

ND

0.83

0.39

ND

20

A

7.3

125.2

ND

ND

ND

54.7

277.3

ND

b

1.10

0.95

ND

ND

ND

1.31

0.53

ND

25

A

11.2

152.7

ND

ND

ND

66.3

287.5

ND

b

1.21

0.69

ND

ND

ND

1.20

0.39

ND

30

A

17.6

193.2

ND

ND

ND

74.7

291.2

ND

b

0.72

1.20

ND

ND

ND

1.41

0.51

ND

80

5

A

36.3 249.4

ND

ND

ND

98.7 375.2 6.10

b

0.67 1.10

ND

ND

ND

1.32 1.43 0.92

10

A

45.6 287.5

ND

ND

25.2 122.7 425.3 9.52

b

1.0 1.20

ND

ND

1.48 1.24 1.22 0.83

15

A

61.3 319.7

ND

ND

37.4 174.2 472.1 12.7

b

1.22 0.90

ND

ND

1.61 1.18 1.50 0.63

20

A

78.5 344.2

ND

ND

51.4 199.7 501.2 18.9

b

0.91 1.09

ND

ND

0.87 0.75 0.54 0.89

25

A

89.3 361.6

ND

ND

74.7 245.6 572.7 29.2

b

1.03 1.03

ND

ND

1.27 0.78 0.54 0.82

30

A

98.6 394.7

ND

ND

94.5 289.2 623.2 37.6

b

1.30 0.94

ND

ND

1.0 0.37 0.78 1.11

Temp

°C

Time

( min )

Mean

And

RSD%

Cl¯

NO2¯

Br¯

NO3¯

HPO4¯¯

SO4¯¯

90

5

A

137.9 485.3

ND

ND

156.7 470.5 693.2 48.7

b

0.47 0.37

ND

ND

1.0 0.39 0.79 1.10

10

A

168.7 535.6

ND

ND

199.7 520.9 773.2 57.8

b

0.54 0.35

ND

ND

0.92 0.75 0.82 0.96

15

A

196.3 596.4

ND

ND

243.3 590.2 842.4 71.6

b

0.62 0.30

ND

ND

1.11 0.78 0.91 0.89

20

A

244.7 646.5

ND

ND

289.6 670.7 966.6 94.3

b

0.75 0.43

ND

ND

0.95 0.87 0.78 0.63

25

A

284.8 698.7

ND

ND

351.7 780.3 1041.2 121.8

b

0.32 0.45

ND

ND

0.96 0.93 0.47 0.72

30

A

355.4 773.7

ND

ND

466.3 890.7 1175.5 137.4

b

0.31 0.44

ND

ND

0.89 0.90 0.57 0.85

In addition, the results shows the relative standard deviation (RSD%) below 1.62%. Figure (9) shows the chromatogram of inorganic anions in Roselle (Hibiscus sabdariffa L.) and it appears its contain only six ions and  from eight ions under investigation and  the absence of both  and

Conclusion

A simple rapid an ion chromatographic method with conductivity detection has been developed for the simultaneous determination of inorganic anions in Roselle (Hibiscus sabdariffa L).

Five ion chromatographic parameters optimized include concentration of both K2CO3 and ETHTC in the eluent, temperature of the eluent, flow rate of the eluent and pH of the eluent.

The analytical method proposed showed a high sensitivity and reproducibility and has the advantage of allowing quantitation of the main mono and divalent inorganic anion. The resulting analysis time was 12.21 minutes and the relative standard deviation (RSD%) below 1.62%. The suggested method may be adapted to the separation and determination of main inorganic anions in other food samples.

References

  1. M. Arienzo, R. Capasso, J. Agric. Food chem.. 48 (2000) 1405.
  2. T. Jauhiainen, J. Moore, P.Peramaki, J. Derome, K. Derome, Anal. Chim. Acta 389 (1999) 21.
  3. N. Gros, B. Gorenc, J. Chromatog. A, 671 (1994) 131.
  4.  John D. Lamb, David Simpson, Bryce D. Jensen, Joseph S. Gardner, Quinn P. Peterson, J. Chromatog. A, 1118 (2006) 100-105.
  5. Masanobu Mori, Kazuhiko Tanaka, Tatsuya satori, Mikaru Ikedo, Wenzhi Hu, Hideyki Itabashi, J. chromatog. A, 1118 (2006) 51-55.
  6. Masanobu Mori, Kazuhiko Tanaka, Murad I. H. Helaleh, Qun Xu, Mikaru Ikedo, Yutaka Ogura, Shinji Sato, Wenzhi Hu, Kiuoshi Hasebe, Paul R. Haddad, J. Chromatog. A, 997 (2003) 219 – 224.
  7. Kazuhiko Tanaka, kazutoku Ohta, Paul R. Haddad, James S.Frits, Akiyashi Miyanaga, Wenzhi Hu, Kiyashi Hasebe, Kwang – Pill lee, Corrado Sazanini, J. Chromatog. A, 920 (2001) 239 – 245.
  8. Ming- Yu Ding, Kazuhiko Tanaka, Wenzhi Hu, Paul R. Haddad, Akiyoshi Miuanaga, J. Liq. Chrom. Rel. Technol., 24 (20), (2001). 3105 – 3117.
  9. Se – Mog Kwon, Kwang – Pill Lee, Kazuhiko Tanaka, Kazutoku Ohta, J. Chromatog. A, 850 (1999) 79-84.
  10. Jong-Hun Kim, Joung-Hae Lee, J. Chromatog. A, 782 (1997) 140 – 146.
  11. Shaker J. Azhari, International Jour Chem. Vol 15. No 3 (2005) 163-178.
  12. Shaker J. Azhari, Mansoura Journal of chemistry, vol 32 (2), December (2005) 85-110.
  13. Shaker J. Azhari, International Jour Chem. Vol. 15 No 4 (2005) 221- 235.
  14. Shaker J. Azhari, International Jour Chem. Vol. 18 No3 (2008) 117-128
  15. S. M. Kwon, K. Lee, K. Tanaka, K. Ohata, Environ. Eng. Res. 4 (1999) 223.
  16. K. Ohata, K. Tanaka, Anal. Chim. Acta 381 (1999) 265.
  17. R. M. Izatt, J. S. Bradshaw, S. A. Nielsen, J. H. Lamb, J. J. Christensen, Chem.. Rev, 85 (1985) 271.
  18. Tee, P. L., Yusof, S., Mohamed, S.,  Nutrition and Food science 32 (1), (2002). 17-20.
  19. Tsai, P. J., Mcintosh, J., Pearce, P., Camden, B., Jordan, B.R., Food Research international 35 (4), (2002). 351-356.
  20. Tsai, P. J., Huang, H. P., Food Research international 37 (4) (2004), 313 – 318.
  21. Tseng, T. H., Kao, E.s., Chu, C.Y., Chou, F.P., Lin wu, H. W., Wang, C.J., Food and Chemical Toxicology 35, (1997). 1159 – 1164.
  22. Prenesti, E., Berto, S., Daniele, P. G., Toso, S., Food chemistry 100 (2), (2007). 433 – 438.
  23. K.I. Emmy Hainida, I. Amin, H.Normah, N. Mohd. Esa. Food chemistry 111 (2008) 906 – 911.
  24. J. Qiu and x. Jin,: J. Chromatography, A, 950 (2002) 81-88.
  25. G.Dugo, T.M. Pellicano, L.L.Pera, V.L. Turco, A. Tamborrion, M. L. Clodveo, Food Chemistry 102, 599 (2007).
  26. Sangita D. Kumar, G. Narayan, S. Hassarajani, Food chemistry 111 (2008) 784-788.
  27. M.M.Mostufa: Spectrochica Acta part A 66 (2007) 480-486.
  28. Shaker J. Azhari, Journal of  Ultra chemistry Vol. 7 (1), 51-64 (2011)