Analytical Application of Phenylazo-Bis-Acetoxime in the Spectrophotometric Determination of Iron (III)
Saba Khan* and Rehana Khanam
Department of Chemistry, M. L. Sukhadia University, Udaipur - 313 001 (India)
Phenylazo-bis-acetoxime has been used for spectrophotometric determination of Iron (III) at 362nm, keeping the pH at 3.5-4.0. Beer’s law is obeyed in the range (4 to 24)x10-5 M. The molar absorptivity and Sandell’s sensitivity values are 1,852 dm3 mol-1 cm -1 and 30.15 ng cm –2, respectively.
KEYWORDS:Arylazo-bis-acetoxime; spectrophotometric determination; Iron (III)
Download this article as:Copy the following to cite this article: Khan S, Khanam R. Analytical Application of Phenylazo-Bis-Acetoxime in the Spectrophotometric Determination of Iron (III). Orient J Chem 2008;24(2). |
Copy the following to cite this URL: Khan S, Khanam R. Analytical Application of Phenylazo-Bis-Acetoxime in the Spectrophotometric Determination of Iron (III). Orient J Chem 2008;24(2). Available from: http://www.orientjchem.org/?p=24920 |