8-Hydroxy-3-p-TolyL-1-o-Nitrophenyltriazene: A New Reagent for Spectrophotometric Determination of Chromium (III)
R. Ressalan, R. S. Chauhan, A. K. Goswami and D. N. Purohit
Department of Chemistry, M.L.S. University, Udaipur, - 313 001 India.
The colour reaction between chromium (111) with 3-hydroxy-3-p-tolyl-1-o-nitrophenyltriazene at 60-65oC in hexamine buffer (pH 5.2 to 6.0) results in the formation of a stable dark grassy green complex. The chromium (III) reagent ratio in this complex is 1:2 with absorption maximum at 510 nm. The molar absorptivity and Sandell's sensitivity values of the complex are 635 L/mole cm and 81.04 ng/cm2 respectively at the working wavelength 514 nm. The Beer's law Is valid over the concentrtion range 1.0 x 104 M of chromium (III). The standard deviation of the method for the determination of the metal is found to be 12.99 ± 0.0015 (0.94%) ppm of chromium The presence of 100 ppm of 15 diverse cations and anions did not interfere with the determination of 12.99 ppm of chromium (III). Thus a useful and simple method for spectrophotometry determination of chromium has been established.
KEYWORDS:Hydroxy; nitrophenyltriazene; absorptivity; spectrophotometry determination
Download this article as:Copy the following to cite this article: Ressalan R, Chauhan R. S, Goswami A. K, Purohit D. N. 8-Hydroxy-3-p-TolyL-1-o-Nitrophenyltriazene: A New Reagent for Spectrophotometric Determination of Chromium (III). Orient J Chem 1998;14(2). |
Copy the following to cite this URL: Ressalan R, Chauhan R. S, Goswami A. K, Purohit D. N. 8-Hydroxy-3-p-TolyL-1-o-Nitrophenyltriazene: A New Reagent for Spectrophotometric Determination of Chromium (III). Orient J Chem 1998;14(2). Available from: http://www.orientjchem.org/?p=22224 |
This work is licensed under a Creative Commons Attribution 4.0 International License.